CPK

rss feed

Service interruptions

A CPK is C&CZ’s way of reporting a problem or service interruption. Follow the mailing list or RSS feed, and check the service interruptions page for live status updates.

A CPK is how C&CZ reports a problem or service interruption. We publish one when something goes wrong, when we need to do planned maintenance, or when we want to let you know about something that affects the services we run.

Note

What’s a CPK? CPK is short for the Dutch C&CZ Probleem Kaart — C&CZ problem card. The name is simply how we’ve always done it, and it has stuck with us ever since.

How to follow CPK messages

CPK messages are first sent to the CPK mailing list — you can (un)subscribe there. You can also follow the service interruption messages via RSS.

When a CPK takes longer to resolve, we publish updates on the service interruptions page.

University-wide interruptions

For Radboud University-wide service interruptions, see meldingen.ru.nl.

 No service interruptions.


Resolved

November 2016

CPK#1189 Some machines down due to failed power distribution unit

Due to a failed power distribution unit (PDU) a network switch powered down. As a result of that the mentioned machines lost their network connectivity. After reconnecting the switch to a different PDU, the machines were reachable again.

Updated May 5, 2026

September 2016

CPK#1188 Servers down due to failed power distribution unit

A few servers powered down due to a failed power distribution unit (PDU), because they were not redundantly connected. After switching to a different PDU, the servers were running again. The redundant connections of important servers will be checked.

Updated May 5, 2026

CPK#1187 RU network maintenance problem

After the maintenance activities as mentioned below, a large number of workplaces of Molecular Biology at RIMLS did not receive an ip-address. After a reset by ISC of a table in the central RU-firewall, the problem was solved.

Updated Oct 8, 2026

CPK#1186 RU network maintenance

In the night of 12 to 13 September, maintenance on the Radboud University network will be performed from 11pm to 03am. Several service interruptions may occur, like internet access via SURFnet, mail via Exchange, Bass, Osiris and Blackboard. We advise to check which systems might be affected by this and if possible shift network activity to a different time slot. You also might think about systems with alerts via Internet.

Updated Oct 8, 2026

CPK#1184 Network drives not available after reboot

After the Monday morning reboot, the Samba network drive service was not running on all Ubuntu 12.04 servers. Reinitializing all Samba configuration files solved the problem. Problems fixed at 08:30 for home servers, 10:25 departmental printers, 12:45 departmental server.

Updated Oct 8, 2026

July 2016

CPK#1185 Digital exam environment not available due to maintenance

Due to maintenance, the digital exam environment will not be available for several hours.

Updated Oct 8, 2026

CPK#1183 Power distribution unit failed

Three cluster nodes powered down due to a failed PDU. After replacing the PDU, the nodes came up normally.

Updated May 5, 2026

June 2016

CPK#1182 Atlas.ti reports: license (almost) expired

When starting Atlas.ti, you get the message that the license expires in a few days or already has expired. There is, however, a three-weeks grace period during which the users will see a warning message but can still use the program normally. The vendor has promised to send the license June 24, and to send it earlier next years. The new license key can be requested from C&CZ.

Updated Oct 8, 2026

May 2016

CPK#1181 License server reboot problem

Due to a problem with a new license the license server didn’t go down for the weekly reboot. When this came to attention, the server was rebooted and the problem was solved. Altera Ansys Accelrys Genesys Hdlworks Idapro Xilinx IntelCompiler Ingr Maple Mathematica Matlab MentorGraphics Mestrelab Topspin Orcad Originlab StateaseRlm

Updated Oct 8, 2026

CPK#1176 License server (lepelaar) reboot problem

Matlab (until 08:45), Origin (09:00), Mestrenova (9:20), Mathematica (9:30) and Orcad (11:20) service not started. Cause yet unknown.

Updated Oct 8, 2026